With the photovoltaic power station, especially the rooftop distributed photovoltaic power generation has been widely popularized. While photovoltaic power generation benefits the people, there are often reports of fire accidents or even accidental personal injury and major property losses due to photovoltaic power plants. Today, let's discuss the fire safety issues that should be paid attention to during the operation and maintenance of photovoltaic power plants.
The DC side of photovoltaic power generation has high voltage and large current. There are many string connectors, and the installation environment is complicated. Many connectors are exposed to sunlight or exposed to wind and rain, which are prone to poor contact and even fire, burning and other fire hazards. Electrical fires are very dangerous, and once they happen, the losses will be heavy. Therefore, the principle of "prevention first" must be implemented to prevent electrical fires before they occur.
Fotovoltaične elektrarne večinoma preprečujejo požare v tokokrogu, vključno z:
· The DC side connector sparks the arc and causes a fire;
· Fire caused by equipment failure (combiner box, inverter, distribution box, transformer, high and low voltage switchgear, etc.);
· Lightning strikes cause fire, etc.
Če se v elektroenergetskih objektih fotovoltaične elektrarne odkrije požar, je treba pretvornik nemudoma izklopiti, prekiniti napajanje izmeničnega toka, nato pa čim prej odklopiti vezje fotonapetostnega niza, da se popolnoma prekine. izklop vira obloka fotonapetostnega niza, da se zagotovi varnost gasilskega osebja in obvladovanje požara v kasnejši fazi. .
V kritični situaciji, da pridobite pobudo za gašenje požara in pridobite čas za obvladovanje požara, lahko požar pogasite z električno energijo pod pogojem, da zagotovite osebno varnost, nato pa prekinite napajanje na ustreznem časa, vendar morate biti pozorni na varnost.
V primeru požara v fotovoltaični elektrarni je treba gasilce čim prej obvestiti in opozoriti, da je fotovoltaična oprema na strehi elektrificirana, gasilci pa naj nosijo izolirne čevlje. Ne dotikajte se telesa ali gasilnega aparata v rokah z žicami pod napetostjo ali električno opremo, da preprečite električni udar med gašenjem.
Fotovoltaične elektrarne bi morale biti opremljene z zadostno opremo za gašenje požara{0}}, vključno z gasilnimi aparati s suhim prahom, gasilnimi aparati z ogljikovim dioksidom, 1211, ogljikovim tetrakloridom ali suhim peskom. Gasilni aparati z vodo in peno so strogo prepovedani pri električnih požarih.
Za pretvornike, krmilnike in druga precizna instrumentna vezja ali električno opremo, kot so motorji, ki vodijo nosilce, na splošno ni primerna uporaba suhega prahu, peska itd. za gašenje požara. Za gašenje požara je treba uporabiti gasilne aparate z ogljikovim dioksidom, 1211 in ogljikovim tetrakloridom. Da bi preprečili, da bi naplavine padle v opremo, povzročajo večje izgube.
Hkrati je treba vzdrževati določeno razdaljo pri uporabi opreme za gašenje požara:
(1) Za telo z napetostjo 10 kV in manj najmanjša razdalja med šobo in napolnjenim telesom ne sme biti manjša od 0,4 m, pri tistih z napetostjo pa 35 kV in več, ne sme biti manjši od 0,6 m;
(2) Če pride do ozemljitvene napake v visokonapetostni-električni opremi ali vodi fotovoltaične elektrarne, notranje reševalno osebje ne sme vstopiti v 4 m od mesta okvare; reševalno osebje na prostem se ne sme približati manj kot 8 m od točke napake. Pri vstopu v zgornji razpon morajo nositi izolacijske čevlje (odporne na nivo napetosti nad 10KV), nositi izolacijske rokavice, ko se dotikajo ohišja in okvirja opreme.